| Precisione | ± 6 mm |
|---|---|
| Temperatura di processo | -60...+400°C (-76...+752°F) |
| Principio di misurazione | Radar di livello |
| Temperatura ambiente | -50...+80 °C (-58...+176 °F) |
| Comunicazione | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Product name | Radar measurement Micropilot FMR62 |
|---|---|
| Process pressure/max. overpressure limit | Vacuum...+25 bar(Vacuum...+362.6 psi) |
| Measuring principle | Level radar |
| Communication | 4...20 mA HART |
| Process temperature | -40...+200 °C (-40...+392 °F) |
| Product name | Radar measurement Micropilot FMR56 |
|---|---|
| Process pressure/max. overpressure limit | Vacuum...3 bar(Vacuum...43.5 psi) |
| Process connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring principle | Level radar solid |
| Product name | Radar measurement Micropilot FMR67 |
|---|---|
| Max. measurement distance | 125 m (410 ft) |
| Process temperature | -40...+200 °C(-40...+392 °F) |
| Measuring principle | Level radar solid |
| Communication | 4...20 mA HART |
| Precisione | ± 6 mm |
|---|---|
| Temperatura di processo | -60...+400°C (-76...+752°F) |
| Principio di misurazione | Radar di livello |
| Temperatura ambiente | -50...+80 °C (-58...+176 °F) |
| Comunicazione | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Product name | Radar measurement Micropilot FMR62 |
|---|---|
| Process pressure/max. overpressure limit | Vacuum...+25 bar(Vacuum...+362.6 psi) |
| Measuring principle | Level radar |
| Communication | 4...20 mA HART |
| Process temperature | -40...+200 °C (-40...+392 °F) |
| Product name | Radar measurement Micropilot FMR56 |
|---|---|
| Process pressure/max. overpressure limit | Vacuum...3 bar(Vacuum...43.5 psi) |
| Process connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring principle | Level radar solid |
| Precisione | ± 6 mm |
|---|---|
| Temperatura di processo | -60...+400°C (-76...+752°F) |
| Principio di misurazione | Radar di livello |
| Temperatura ambiente | -50...+80 °C (-58...+176 °F) |
| Comunicazione | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Temperatura ambiente | -50...+80 °C (-58...+176 °F) |
|---|---|
| Lunghezza del sensore | Sonda ad asta: 10 m /Sonda a corda: 45 m /Sonda coassiale: 6 m |
| Comunicazione | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Pressione di processo/Max. limite di sovrapressione | Vuoto...400 bar (Vuoto...5800 psi) |
| Principio di misurazione | Radar guidato |
| Materiale | Acciaio inossidabile |
|---|---|
| Principio di misurazione | Radar guidato |
| Pressione di processo/Max. limite di sovrapressione | Vuoto...400 bar (Vuoto...5800 psi) |
| Comunicazione | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Temperatura ambiente | -50...+80 °C (-58...+176 °F) |